Sign In | Join Free | My udpf.com |
|
Brand Name : Long
Model Number : 3.6-42KV
Certification : ISO
Place of Origin : China
MOQ : 1piece
Payment Terms : T/T, D/P, D/A, L/C, Western Union, MoneyGram
Supply Ability : 400000pieces per day
Delivery Time : 1-9days
Packaging Details : bag/Carton
Feature : Electrical stress control
Used for : For MV Cables
Insulation : Insulation and screen
Shielding : Metallic shielding
Protection : Outer sealing
The outer sealing and protection : is performed by an adhesive coated
Straight joint for screened : 1 -core polymeric insulated cables 6kV, 10kV, 20kV, 30kV and 35kV and 42KV
Note : Connectors need to be ordered separately.
Heat Shrink Joints For MV Cables Up To 42kV For MV Screened For 1.Electrical Stress Control
The joints are designed for MV screened, 1 -core polymeric insulated cables with or without armour. The
same design principles are used for 3-core cables.
1. Electrical stress control
Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen ends.
2. Insulation and screen
Heat shrink insulation tube delivers consistent insulation thickness to meet or exceed that of the cable.
Heat shrink semi-conductive /insulation dual layer tube is also adopted to help ensure a void-free interface between the insulation and screen.
3 . Metallic shielding
Copper mesh wrapped around the joint area rebuilds the metallic screen. Either soldering or solderless earth connection is available to provide
screen continuity across the joint.
4 . Outer sealing and protection
The outer sealing and protection is performed by an adhesive coated, heat shrink tube. It provides mechanical protection and chemical resistance
as expected from cable oversheath.
Straight joint for screened, 1 -core polymeric insulated cables 6kV, 10kV, 20kV, 30kV and 35kV and 42KV
The joint is designed for screened single core polymeric insulated MV cables up to 42kV.
Stress control tube, together with stress relief mastic, is used to smooth out the electrical field at the cable screen ends. Heat shrink insulation
tube delivers consistent insulation thickness over the core insulation. Heat shrink dual layer tube is adopted to help ensure a void-free interface
between the insulation and screen. Copper mesh wrapped around the joint area rebuilds the metallic screen. Either soldering or solderless earth
connection is available to provide screen continuity across the joint. The outer sealing and protection is performed by an adhesive coated heat
shrink tube.
Selection Table | / | ||||
Nominal voltage | Cross section (mm2) | Kit No. | L | ||
25-50 | 6kVRSJY | 1/1 | 820 | ||
70-120 | 6kVRSJY | 1/2 | 820 | ||
150-240 | 6kVRSJY | 1/3 | 820 | ||
3.6/6(7.2)kV | 300-400 | 6kVRSJY | 1/4 | 820 | |
500-630 | 6kVRSJY | 1/5 | 820 | ||
800-1000 | 6kVRSJY | 1/6 | 820 | ||
1200 | 6kVRSJY | 1/7 | 820 | ||
25-50 | 10kVRSJY | 1/1 | 820 | ||
70-120 | 10kVRSJY | 1/2 | 820 | ||
6/10(12)kV | 150-240 | 10kVRSJY | 1/3 | 820 | |
6.35/11(12)kV | 300-400 | 10kVRSJY | 1/4 | 820 | |
8.7/15(17.5)kV | 500-630 | 10kVRSJY | 1/5 | 820 | |
800-1000 | 10kVRSJY | 1/6 | 820 | ||
1200 | 10kVRSJY | 1/7 | 820 | ||
35-50 | 20kVRSJY | 1/1 | 820 | ||
70-120 | 20kVRSJY | 1/2 | 820 | ||
12/20(24)kV | 150-240 | 20kVRSJY | 1/3 | 820 | |
300-400 | 20kVRSJY | 1/4 | 1020 | ||
12.7/22(24)kV | 500-630 | 20kVRSJY | 1/5 | 1020 | |
800-1000 | 20kVRSJY | 1/6 | 1020 | ||
1200 | 20kVRSJY | 1/7 | 1020 | ||
35-50 | 30kVRSJY | 1/1 | 1100 | ||
70-120 | 30kVRSJY | 1/2 | 1100 | ||
18/30(36)kV | 150-240 | 30kVRSJY | 1/3 | 1100 | |
300-400 | 30kVRSJY | 1/4 | 1100 | ||
500-630 | 30kVRSJY | 1/5 | 1100 | ||
800-1000 | 30kVRSJY | 1/6 | 1100 | ||
1200 | 30kVRSJY | 1/7 | 1100 | ||
50 | 35kVRSJY | 1/1 | 1100 | ||
70-120 | 35kVRSJY | 1/2 | 1100 | ||
20.8/36(42)kV | 150-240 | 35kVRSJY | 1/3 | 1100 | |
300-400 | 35kVRSJY | 1/4 | 1160 | ||
500-630 | 35kVRSJY | 1/5 | 1160 | ||
800-1000 | 35kVRSJY | 1/6 | 1160 | ||
1200 | 35kVRSJY | 1/7 | 1160 |
Note:
1 .Connectors need to be ordered separately.
2.RSJY-1 is for cables with copper wire screen without armour.
3.Solderless earth connection have to be ordered separately as follows:
•For cables with copper wire screen and wire armour, add suffix -WA. For example, 6kVRSJY-1/1 -WA.
•For cables with copper tape screen with armour wire,add suffix -X. For example, 6kVRSJY-1/1 -X.
![]() |
Outer Sealing Heat Shrink Cable Joint 42kv Heat Shrink Cable Accessories Metallic Shielding Images |